boiler saturated steam lb hr bhp

  • Offshore price : $20000-$100000 Get a quote on the right form
  • Minimum order quantity : 1 set :boiler saturated steam lb hr bhp
  • Supply Capacity : 10 units/month :boiler saturated steam lb hr bhp
  • Manufacturer/Brand : Fangkuai boiler
  • Port : Anyang
  • payment terms : Letter of Credit, Wire Transfer, VISA

Leave Your Message And Get Price!

I need the quotation of , the fuel is , this capacity is , use for . My Name is , my Email is , my WhatsApp is , Please Send the detail information for me!

Popular products

HOT

θrion Gas Fired Steam Boiler

Capacity:1-20t/h

Rated thermal efficiency: 100-104%

Fixed working pressure: ≤1.6MPa

Applicable fuel:natural gas etc.

consult
HOT

Gas(oil) Fired Integrated Hot Water Boiler

Capacity:0.7-14MW

Rated thermal efficiency:96-98%

Fixed working pressure:≤1.25MPa

Applicable fuel:Natural gas, light oil, etc.

consult
HOT

H6 Gas Fired Hot Water Boiler

Capacity:0.7-2.8Mw

Rated thermal efficiency: 97.2-106%

Fixed working pressure:0.1MPa

Applicable fuel:Natural gas, etc.

consult
HOT

T7 Vacuum Hot Water Boilerr

Capacity:2.8-7.0Mw

Rated thermal efficiency:≥105.5%

Fixed working pressure:-0.02MPa

Applicable fuel:Natural gas, etc.

consult
HOT

V6 Gas Fired Hot Water Boiler

Capacity:99Kw

Rated thermal efficiency:97.2-104.4%

Fixed working pressure:1.0MPa

Applicable fuel:Natural gas, etc.

consult
HOT

Electric Steam Boiler

Capacity:0.5-4.0 t/h

Rated thermal efficiency:98%

Fixed working pressure:≤1.25MPa

Applicable fuel:electric energy

consult

Leave us a message

We will send out plans and quotations within five minutes

Name (optional)

Email

Whatsapp

Choose product type

Message

Get display discount

Contact us

Global Sales Hotline:
0086-371-60922096

Email: [email protected]

Voicemail
  • Compre Special Project (PPE &IPE) | PDF | Boiler | Thermal

    A surface condenser serving a 50,000 kW steam turbo-generator unit receives exhaust steam at the rate of 196,000 kg/hr. Vacuum in condenser is 702 mm. Hg. Sea. water for cooling enters at 29 and leaves at 37.5 C . For steam turbine condenser, manufacturers consider 950 Btu/lb of steam turbine condensed as heat given up to cooling water Get Price

  • Compre Special Project (ppe &ipe) [vnd5gjm03rlx]

    Steam at the rate of 70,000 kg/hr from the boiler drum enters the superheater inlet header at 8.3 Mpa and 485oC. Combustion products at 980oC enters the superheater proper at the rate of 160,000kg/hr. Superheater elements are made of 60 mm O.D. by 8 …Get Price

  • Compre Special Project (ppe &ipe) [vnd5gjm03rlx]

    Steam at the rate of 70,000 kg/hr from the boiler drum enters the superheater inlet header at 8.3 Mpa and 485oC. Combustion products at 980oC enters the superheater proper at the rate of 160,000kg/hr. Superheater elements are made of 60 mm O.D. by 8 …Get Price

  • Board Exam1 | PDF | Enthalpy | Pressure - Scribd

    A boiler with a steam rating of 200,000 lb/hr will be fired with the above fuel having a high heat value of 12,200 BTU/lb. if the boiler efficiency is 80%, and if it takes 1000 BTU to evaporate and superheat one pound of feedwater to the desired temperature, find the hourly coal supply and grate area neened.Get Price

  • Heating Oil - Boilers - Heaters - The Home Depot

    Slant/Fin Intrepid Oil Steam Boiler with 98,000 BTU Output. Model# TR-30-PZ (1) $ 3171 32 /pallet. MorrHeat Waste Oil Fired Boiler with 360,000 BTU Input. Model# MHB360 $ 12915 00 /pallet. Rand and Reardon RRO Series 87% AFUE Oil Water Boiler without Coil and 129,000 BTU - 158,000 BTU Output.Get Price

  • Chapter 4: [CE] Commercial Energy Efficiency, 2020 Energy

    Boiler systems with design input of greater than 1,000,000 Btu/h (293 kW) shall comply with the turndown ratio specified in Table C403.3.4. The system turndown requirement shall be met through the use of multiple single-input boilers, one or more modulating boilers or a combination of single-input and modulating boilers. TABLE C403.3.4. BOILER Get Price

  • Compre Special Project (PPE &IPE) | PDF | Boiler | Thermal

    A surface condenser serving a 50,000 kW steam turbo-generator unit receives exhaust steam at the rate of 196,000 kg/hr. Vacuum in condenser is 702 mm. Hg. Sea. water for cooling enters at 29 and leaves at 37.5 C . For steam turbine condenser, manufacturers consider 950 Btu/lb of steam turbine condensed as heat given up to cooling water Get Price

  • Home - Steam Boiler Sales Specialists - Tomlinson Energy

    As Australia's boiler specialists, we provide 24/7 emergency and service support to the Asia-Pacific markets — supplying economical, high-efficiency packages for steam boilers, hot water & thermal oil heaters.Get Price

  • Project Standards and Specifications Steam Boiler Systems

    4. Boiler shall be designed for the following operating conditions: a. Guaranteed net steam capacity, for each boiler at superheater outlet excluding all blow down, heat losses and all steam used for boiler auxiliaries such as fans, soot blowers, burners, etc., as specified on data sheet b.Get Price

  • Board Exam1 | PDF | Enthalpy | Pressure - Scribd

    A boiler with a steam rating of 200,000 lb/hr will be fired with the above fuel having a high heat value of 12,200 BTU/lb. if the boiler efficiency is 80%, and if it takes 1000 BTU to evaporate and superheat one pound of feedwater to the desired temperature, find the hourly coal supply and grate area neened.Get Price

  • Steam boiler Automatic & Manual Water Feeder Valves

    Water feeder valves on steam heating boilers Automatic water feeder valves on steam boilers What system pressure settings are needed for hot water heat When, how often, and how much water to add to the steam boiler Backflow preventers built into steam boiler automatic water feeders Questions & answers about how and when to use and maintain the water feed valve on …Get Price

  • Basic Power and Industrial Plant Engineering - VSIP.INFO

    Boiler - 14 (ME Bd. Apr. 1984) A boiler operating at 11 kgicm 1 is required to generate a minimum of 50,000 kg/hr of saturated steam. Feed water enters the boiler at 80°C. The furnace is designed to fire coal at an average rate 4,800 kg/hr and boiler efficiency is 85%. Compute the minimum heating value of localGet Price

  • boiler | engineering | Britannica

    boiler, apparatus designed to convert a liquid to vapour. In a conventional steam power plant, a boiler consists of a furnace in which fuel is burned, surfaces to transmit heat from the combustion products to the water, and a space where steam can …Get Price

  • Buy Industrial Steam Boilers | Commercial Steam Boiler

    Miura's EX industrial boilers are incredibly versatile high-pressure steam systems that may be used with natural gas, propane, or #2 fuel oil. The EX offers NOx ratings as low as 30 ppm depending on the model and a compact footprint that occupies 33% less boiler room space than a typical fire tube boiler.Get Price

  • Basic Power and Industrial Plant Engineering - VSIP.INFO

    Boiler - 14 (ME Bd. Apr. 1984) A boiler operating at 11 kgicm 1 is required to generate a minimum of 50,000 kg/hr of saturated steam. Feed water enters the boiler at 80°C. The furnace is designed to fire coal at an average rate 4,800 kg/hr and boiler efficiency is 85%. Compute the minimum heating value of localGet Price

  • Combustion Evaluation: Sources and Control Devices

    The available heat for the boiler at 500°F and theoretical combustion equals 9, 150,000 BTU per hour. d. Good atomizers on clean fuel use only 0.1 Ibs of steam/lb of oil but consumption may rise to 1 Ibs/lb if poorly adjusted. of gas and air flow A knowledge of furnace temperature is less important in boilers which make saturated steam Get Price

  • Project Standards and Specifications Steam Boiler Systems

    4. Boiler shall be designed for the following operating conditions: a. Guaranteed net steam capacity, for each boiler at superheater outlet excluding all blow down, heat losses and all steam used for boiler auxiliaries such as fans, soot blowers, burners, etc., as specified on data sheet b.Get Price

  • Chapter 4: [CE] Commercial Energy Efficiency, 2020 Energy

    Boiler systems with design input of greater than 1,000,000 Btu/h (293 kW) shall comply with the turndown ratio specified in Table C403.3.4. The system turndown requirement shall be met through the use of multiple single-input boilers, one or more modulating boilers or a combination of single-input and modulating boilers. TABLE C403.3.4. BOILER Get Price

  • Combustion Evaluation: Sources and Control Devices

    The available heat for the boiler at 500°F and theoretical combustion equals 9, 150,000 BTU per hour. d. Good atomizers on clean fuel use only 0.1 Ibs of steam/lb of oil but consumption may rise to 1 Ibs/lb if poorly adjusted. of gas and air flow A knowledge of furnace temperature is less important in boilers which make saturated steam Get Price